APNI BIJLI BANAO, EXPERT KO BULAO.
SOLAR KE SMART SOLUTIONS GHAR LE AAO!
Call: +91 9999 039 039
SUPER SAVINGS
@LivguardEnergy Livguard Energy @livguardenergy @LivguardEnergy Livguard
Livguard Energy Technologies Private Limited Plot no. 221, Udyog Vihar Phase-I, Gurgaon-122016, Haryana, India.
LIVGUARD SOLAR PRODUCT RANGE
SOLAR PANEL
40 WATT – 545 WATT
SOLAR MANAGEMENT UNIT
30 A - 50 A
A BOUT LIVG UARD
Livguard Energy Technologies Pvt. Ltd. (LETPL) one of India’s leading providers for power energy solutions is poised to transform the world with its cutting edge technology, in solar solutions, power back-up, automotive solutions, & e-rickshaw batteries. Livguard was founded in the year 2014 and is a part of the SAR Group which has been serving the nation for the past three decades. With our technologically advanced toolkit and trained technicians we have achieved the customer’s trust and faith in our products and services. This has helped us reach the 4,000 crore company milestone in a short period of time.
SOLAR CHARGE CONTROLLER
10 A– 50 A
SOLAR BATTERY
40 AH – 240 AH
SOLAR UPS
700 VA – 2200 VA
PWM POWER CONDITIONING UNIT
3.5 KVA – 10 KVA

SOLAR UPS MPPT
1000 VA – 2500 VA
MPPT POWER CONDITIONING UNIT
3 KVA – 15 KVA
GRID INTERACTIVE HYBRID
1-PHASE : 3KVA - 5KVA
3-PHASE : 10KVA - 30KVA
SOLAR PANEL
Livguard Solar Panels are available in Poly-crystalline and
Mono PERC PV cells, with IEC compliance ranging for 40Wp
- 545Wp panels. Our Panels are ideally suited for rooftop and agricultural applications.
MODULE 12V
| Model NamePower (pm) in Watts (Nominal) | LGV12V40 | LGV12V50 | LGV12V75 | LGV12V100 | LGV12VS150 | LGV12V180M |
|---|---|---|---|---|---|---|
| 40 | 50 | 75 | 100 | 150 | 180 | |
| No. of Cells | 36 | 36 | 36 | 36 | 32 | 32 |
| Rated Module Voltage | 12 | 12 | 12 | 12 | 12 | 12 |
| Voltage at Maximum Power (Vmp) in Volts | 17.5 | 18 | 18 | 18 | 16.9 | 18.01 |
| Current at Maximum Power (Imp) in Amps | 2.46 | 2.78 | 4.17 | 5.66 | 8.9 | 9.99 |
| Open Circuit Voltage (Voc) in Volts | 21 | 22 | 22 | 22 | 21.6 | 22.12 |
| Short Circuit Current (Isc) in Amps | 2.54 | 3.28 | 4.67 | 6.06 | 9.2 | 10.37 |
| Maximum System Voltage (VDC) | 600 | 600 | 600 | 600 | 1000 | 1000 |
| ŋ (%) | >12% | >12% | >14% | >14% | >16% | >18% |
| STC: Irradiance 1000W/M2, Ambient Temperature 25°C, Air Mass 1.5, Measuring Tolerance ± 3% |
Excellent Performance in low light
High quality transparent glass Glossy EVA to capture maximum solar energy
Positive Power Tolerance
Ensures full energy harvesting Ensures better return on investment
12*
Years Product Warranty
Years Performance Warranty
Suitable for Extreme Weather Tempered glass withstands dynamic wind load of 2400 Pa & snow
25
load of 5400 Pa
Multi EVA capsulation
MODULE 24V
| Model Name | |||||
|---|---|---|---|---|---|
| 335 | 400 | 530 | 535 | 540 | 545 |
| 72 | 72 | 144 | 144 | 144 | 144 |
| 24V | 24V | 24V | 24V | 24V | 24V |
| 38.3 | 41.2 | 41.36 | 41.43 | 41.81 | 42.02 |
| 8.75 | 9.72 | 12.82 | 12.92 | 12.92 | 12.98 |
| 46.5 | 49.79 | 49.32 | 49.47 | 49.81 | 50.14 |
| 9.35 | 10.31 | 13.7 | 13.81 | 13.51 | 13.55 |
| 1000 | 1500 | 1500 | 1500 | 1500 | 1500 |
| 17.35 | 20.17 | 20.54 | 20.94 | 20.94 | 21.12 |
| 2 |
WARRANTY & CERTIFICATION
| Product Warranty* | 5 years for 12V Modules; 12 Years for 24V Modules |
|---|---|
| Performance Warranty* | |
| IS:14286, IS-61215, IS-61730 |
PID
Potential-Induced Degradation (PID) Resistance Technology
*Refer solar module warranty card document
FREE For longer life and lower degradation
Technical Parameters are subject to change without any prior notice

*12 years product warranty is applicable on the 24V Modules with new warranty T&C mentioned. Refer Warranty Card or Visit our website www.livguardsolar.com to know more on warranty T&C.
SOLAR MANAGEMENT UNIT
Livguard Solar Management Unit (SMU) converts any existing inverter into solar system. It has in-built intelligence to maximize use of solar energy and is ideal for various DC voltages.
1
| W | arranty | Years | Auto bypass |
|---|---|---|---|
| during fault | LCD Display | Easy to operate, in-built interactive LCD Display indicates alert & system status | SOLAR MANAGEMENT UNIT |
| Model Name | LSMU 122430 | LSMU 24-4850 | |||
|---|---|---|---|---|---|
| Solar Management Unit Rating | 12/24V @ 30A | 24V @ 50A | 36V @ 50A | 48V@ 50A | |
| Technology | Micro Controller Unit based PWM | ||||
| Type | Series Regulator Common Positive | ||||
| System Voltage | 12V | 24V | 24V | 36V | 48V |
| Setting | Auto Sensing | Settable (Default 48V) | |||
| Maximum Solar Panel (Wp) | 500W | 1000W | 1800W | 3600W | |
| Maximum Solar Panel Voltage | 50V | 90V |
BATTERY SETTINGS
| Bulk Voltage | Range | 13.9 - 15.9V | 27.9 - 31.8V | 41.7 - 47.7V | 55.6 - 63.6V |
|---|---|---|---|---|---|
| Default | 14.2V | 28.4V | 42.6V | 56.8V | |
| Float Voltage | Range | 13.3 - 14.1V | 26.6 - 28.2V | 39.9 - 42.3V | 53.2 - 56.4V |
| Default | 13.5V | 27V | 40.5V | 54V | |
| Low Battery | 10.5 ± 0.2V | 21 ± 0.2V | 31.5 ± 0.2V | 42 ± 0.2V |
LOAD CONTROLLER
| Grid Disconnect from Inverter (Voltage) | After Battery goes to Bulk Charge Mode & PV Energy Available | ||||
|---|---|---|---|---|---|
| Grid Re-connect to Inverter (Voltage) | 12.7V Default Setting Settable Range:11.4 - 13.3V | 25.4V Default Setting Settable Range:22.8 - 26.6V | 25.4V Default Setting Settable Range:22.8 - 26.6V | 38.1V Default Setting Settable Range:34.2 - 39.9V | 50.8V Default Setting Settable Range:45.6 - 53.2V |

Maximize Solar Yield Engineered to extract maximum power from solar, to reduce the electricity bill.
Protections
In-built short circuit , reverse current & polarity protection
No risks of electric shocks
3 Stage Intelligent Battery Charge Profile
Designed to track the battery charging profile (Bulk, Absorption, and Float) Enhances battery life.
PROTECTIONS & USER INTERFACE
| Protection | Reverse Polarity for PV/Battery, Short Circuit, Battery Overcharge & Deep Discharge | |
|---|---|---|
| User Interface | LED Indications | Faults: Battery Low & High, Reverse Current, Panel Charging Overcurrent |
| Battery Charging Status | ||
| LCD Display | PV Current/Voltage | |
| Battery Current/Voltage | ||
| Faults: Battery Low & High, Reverse Current, Charging Overcurrent | ||
| KWh Generated from Solar (Cumulative - kWh, Instantaneous - KW) |
GENERAL
| Operating Temperature | 0°C to 50°C | |
|---|---|---|
| Dimensions (LxWxH) in mm | 205 x 113 x70 | 264 x 183 x 90 |
| Weight (Kg) | 0.8 | 1.57 |
Technical Parameters are subject to change without any prior notice
SOLAR CHARGE CONTROLLER
Livguard Solar Charge Controller is an advanced micro controller unit based on PWM technology. The charging process has been optimized for longer battery life and improved system efficiency.
SOLAR CHARGE CONTROLLER

Automatic Voltage Selection Auto battery selection upto 20 A Settable battery selection for 50 A
Increase Battery Life /Gravity Builder
Designed to remove sulphate build up A high equalizing charged battery
Dusk
to Dawn
Protections
In-built short circuit , reverse current & polarity protection
No risk of electric shocks
Years Warranty
USB Port
1
USB Port available for mobile charging
For 20A plug in your DC devices such as fans and lights
BATTERY SETTINGS
| Model Name | LSCC 122410 | LSCC 122420 | LSCC 24-4850 | ||
|---|---|---|---|---|---|
| Charge Controller Rating (Amp.) | 12/24V @ 10A | 12/24V @ 20A | 24V @ 50A | 36V@ 50A | 48V@ 50A |
| Technology | Micro Controller Unit Based PWM | ||||
| Type | Series Regulator Common Positive | ||||
| System Voltage | 12 / 24 V | 24 / 36 / 48V | |||
| Setting | Auto Sensing | Settable (Default 48 V) | |||
| Maximum Solar Panel (Wp) | 12V @ 160W24V @ 335W | 12V @ 335W24V @ 600W | 1800W | 3600 W | |
| Maximum Solar Panel Voltage | 60V | 90V |
| Voltage | 12V | 24V | 24V | 36V | 48V |
|---|---|---|---|---|---|
| Bulk Voltage (V) | 14.2V | 28.4 | 27.8V - 31.8V | 41.7V - 47.7V | 55.6V - 63.6V |
| Default Voltage (Bulk) | 28.4V | 42.6V | 56.8V | ||
| Float Voltage (V) | 13.5 | 27V | 26.6V - 28.2V | 39.9V - 42.3V | 53.2V - 56.4V |
| Default Voltage (Float) | 27V | 40.5V | 54V | ||
| Low Battery (V) | 10.5V ± 0.2V | 21.0V ± 0.2V | 31.5V ± 0.2V | 42.0V ± 0.2V |
PROTECTIONS & USER INTERFACE
| Protection | Reverse Polarity (Panel/Battery), Short Circuit, Battery Overcharge & Deep Discharge | ||
|---|---|---|---|
| User Interface | Display & Indications | LED | LED & LCD |
| LED Indications | Faults: Battery Low & High, Reverse Current, Panel Charging Overcurrent | ||
| Battery Charging Status | |||
| LCD Display | NA | Solar PV Power | |
| Battery Voltage | |||
| Charging Mode | |||
| Load On/Off | |||
| Faults: Battery Low & High, Reverse Current, Charging Overcurrent | |||
| Charging Status |
GENERAL
| Operating Temperature | 0°C to 50°C | ||
|---|---|---|---|
| Dimensions (LxWxH) in mm | 112 x 125 x 25 | 125 x 100 x 45 | 264 x 183 x 90 |
| Net Weight (Kg) | 0.32 | 0.45 | 1.48 |
Technical Parameters are subject to change without any prior notice
SOLAR BATTERY
Livguard Solar Batteries are C10 rated deep cycle batteries. Innovative Super Tuff 3D design and extra thick tubular plates gives longer backup & battery life.
| 5 | SOLAR BATTERY | Super Tuff | 3D design Plates | Up to | Years Warranty |
|---|---|---|---|---|---|
| Superior Life Cycle | Ensures longer battery service life Life Cycle- 2000 at 80% depth of discharge at Room Temperature | Super Tuff 3D Grid | Industry’s 1st 3D design with double side pasting | Ensures longer battery life | pre wedding shoot |
| Model Name | Nominal Voltage (V) | Capacity @ C10 (Ah) | Battery Weight with Acid ± 3% (Kg) | Overall Dimension | Free Replacement (Months) | Pro Rata Warranty (Months) | ||
|---|---|---|---|---|---|---|---|---|
| Length ± 3 mm | width ± 3 mm | Height ± 3 mm | ||||||
| LS4036ST | 12 | 40 | 23.4 | 410 | 175 | 235 | 0 - 36 | - |
| LS7536ST | 12 | 75 | 30.1 | 410 | 175 | 271 | 0 - 36 | - |
| LS10060TT | 12 | 100 | 52.3 | 505 | 188 | 410 | 0 - 60 | - |
| LS13560TT | 12 | 135 | 55.7 | 505 | 188 | 410 | 0 - 60 | - |
| LS15060PTT | 12 | 150 | 53.2 | 505 | 188 | 410 | 0 - 36 | 37 - 60 |
| LS16560TT | 12 | 165 | 55 | 505 | 188 | 410 | 0 - 60 | - |
| LS18060PTT | 12 | 180 | 57.5 | 505 | 188 | 410 | 0 - 36 | 37 - 60 |
| LS20060TT | 12 | 200 | 63.4 | 505 | 188 | 410 | 0 - 60 | - |
| LS24060PTT | 12 | 240 | 70.0 | 505 | 188 | 410 | 0 - 36 | 37 - 60 |
Advanced premium design
Robust high quality durable material
Note: Battery Capacity is C10 upto 1.80 Volts per Cell at 27°C
Applications
| . Solar Rooftop Projects | . Solar Home Lights | . Solar Street Lights | . Solar UPS | . Solar Management Unit |
|---|---|---|---|---|
| . Solar Charge Controller |  | . Telecom Towers | Ultra Low Maintenance | Topping up frequency – Initially 8 to 10 Months |
SOLAR UPS
Livguard Solar Hybrid UPS provides power from solar battery and
grid as per the load profile. It has the highest rated solar charge controller which extracts maximum power from solar modules and reduces electricity bills.
2
SOLAR UPS
| System Rating | 700 VA | 900 VA | 1500 VA | 1500 VA | 2200 VA |
|---|---|---|---|---|---|
| Nominal Battery Voltage (Vdc) | 12 V | 24 V | |||
| Output Waveform | Pure Sine Wave | ||||
| Switching Element | MOSFET |
SOLAR PV INPUT
Model Name LS OG950 LS OG1150+ LS OG1750/12V LS OG1850+ LS OG2250+
| Technology | PWM | |
|---|---|---|
| Charge Controller Rating (Amps.) | 50 A | |
| Maximum Solar Panel (Wp) | 900 Wp | 2000 Wp |
| Input Voltage Range (Vmp) | 14.5-18 V | 29 - 42 V |
| Maximum Input Voltage (Voc) | 25 V | 50V |
Highest Rated Solar Charge Controller
Auto bypass
during fault
Years Warranty
GRID INPUT
| Input Supply | Single Phase -230V, 50Hz |
|---|---|
| Operating Voltage Range (Normal Mode ) | 90 V - 290 V |
| Operating Voltage Range (UPS Mode ) | 180 V - 260 V |
Real Time Clock (RTC) Technology In-built intelligence RTC to maximize solar energy utilization.
Optimized solar energy utilization based on localized power situation
OUTPUT
| No Load Output Voltage | 225V + 7V | |
|---|---|---|
| Output Frequency Battery Mode | 50 ± 1Hz | |
| No Load Current (UPS Swich Off) | ≤ 180mA | ≤ 200mA |
BATTERY
| Battery Charging through Mains + (NC) | 10 A | 13 A | 17 A | 13 A | 14 A |
|---|---|---|---|---|---|
| Battery Charging through Mains + (HC) | 13 A | 17 A | 24 A | 17 A | 20 A |
| Battery Charging through Solar (Default) | 40 A | ||||
| Charging Current @100V AC | >8 A | ||||
| Low Battery Indication | 10.8± 0.2V | ||||
| Low Battery Trip | 10.6± 0.2V | ||||
| Solar Optimization after Battery is Fully Charged | If Solar is Available - then Load is Handled by Battery & Solar |

Fast Battery Charging
In-built 50A solar charge controller Charges the battery in short time
User Friendly LCD Display
Easy to operate, in-built interactive LCD display indicates alarm & system status including solar generation
Pure Sine Wave
Noiseless operations & long life of electrical appliances
Safety & Protection
In-built Inverter, panel, & battery protections
Under/over voltage protection in bypass mode
UPS/Normal Mode
Suitable for computer load as well as areas with low voltage
OVERLOAD , PROTECTION , LCD DISPLAY & USER INTERFACE
| Overload Shutdown Indication | Display Overload & Alarm |
|---|---|
| Overload Pre-Alarm Indication | Display Overload with Load % Alarm |
| Overload Capacity | 110% Load Running at 3 Sec |
| Protection | Thermal Trip , OverLoad with % , Short Circuit , Battery Low , PV Reverse , Fuse Trip |
| LCD Display | Mains Voltage / Output Voltage , Battery Voltage , Load(%), Battery Low , Solar KWH Solar Ciurrent on Load , Solar Charging Current , Overload with (%), PV Reverse, Short Circuit. |
| User Interface | Battery Boost Voltage , Battery Low Cut Voltage, Max, Grid Charging Current, Max.Solar Charging Curent. |
GENERAL
| Operating Temperature | 0°C to 50°C | ||||
|---|---|---|---|---|---|
| Dimensions(LxWxH) in mm | 335325180 | 295 X 330 X 170 | 335325180 | 363 X 398 X 251 | 365 X 400 X 250 |
| Net Wieght (Kg) | 7.52 | 10 | 11.36 | 15 | 16.5 |
| Technical Parameters are Subject to Change Without any Perior Notice. |
PWM POWER CONDITIONING UNIT
Livguard Solar Hybrid PCUs are high capacity, high efficiency solar UPS that runs both on solar & utility (grid) power supply. It has an in-build solar charge controller which extracts maximum power from solar modules to power your appliances & battery charging.
2
& LED Display
Years Warranty
Real Time Clock (RTC) Technology In-built intelligence RTC to maximize solar energy utilization.
Optimized solar energy utilization based on localized power situation
PWM POWER CONDITIONING UNIT
| Model NameSystem Rating | LS OGR3500 | LS OGR5048 | LS OGR7500 | LS OGR10000 |
|---|---|---|---|---|
| 3.5 KVA | 5 KVA | 7.5 KVA | 10 KVA | |
| Nominal Battery Voltage (Vdc) | 48V | 48V | 120V | 120V |
| Ouput Waveform | Pure Sine Wave | |||
| Switching Element | MOSFET |
SOLAR PV INPUT
| Technology | PWM | |||
|---|---|---|---|---|
| Charge Controller Rating (Amps.) | 50 A | 70 A | 50 A | 70 A |
| Maximum Solar Panel (Wp) | 3400W | 5600W | 8500W | 11900W |
| Maximum Input Voltage (Vmp) | 82.4 | 82.4 | 188 | 188 |
| Maximum Input Voltage (Voc) | 100 | 100 | 230 | 230 |
GRID INPUT
| Input Supply | Single Phase - 230 V; 50 Hz |
|---|---|
| Nominal Voltage Range | 100 - 280V |
| Nominal Frequency Range | 45 - 55Hz |
OUTPUT
| Nominal Output (Vac) | 220V ± 7V | |||
|---|---|---|---|---|
| Nominal Frequency | 50Hz ± 1Hz | |||
| Nominal Output Current (A) | 12.5Amp. | 17.5Amp. | 27Amp. | 35Amp. |
| ≥ 80% | ≥ 85% |
BATTERY
| Battery Recharge Current Range from Grid Side (A) | 5 - 18A | 5 - 16A | 5 - 20A |
|---|---|---|---|
| Default Value Battery Recharge Current Range from Grid Side (A) | 18A | 16A | 20A |
| Battery Recharge Current Range from PV Side (A) | 5 - 50A |
Fast Battery Charging

In-built 50/70 Amp solar charge controller that charges the battery in short time
User Friendly LCD Display
Easy to operate, in-built interactive LCD display indicates alarm & system status including solar generation
Pure Sine Wave
Noiseless operations & long life of electrical appliances
Safety & Protection
In-built human, panel, & battery protections
No risk of electric shocks
UPS Mode
Suitable for computer load as well as areas with low voltage
PROTECTION, USER INTERFACE & SETTING
| Protection | Thermal Trip, Over load with %, Short Circuit, Battery Low, PV Reverse, MCB Trip |
|---|---|
| LCD Display | Mains on/off/cut, Mains Voltage, Battery Voltage, Battery Charging/Charged, Mode: UPS/NormalLoad (%), Solar On/Off, Solar to Load (A), Solar to Battery (A) |
| Indications | Inverter: On/Off, Charging: high/low, Mode: UPS/Normal, Mode: Hybrid |
| User Setting | Battery Boost Voltage, Battery Low Cut Voltage, Max. Grid Charging Current, Max. Solar Charging Current |
ENVIRONMENT
| IP Protection Level | IP-20 |
|---|---|
| Operating Temperature (°C) | 0 to + 55°C |
| Max Relative Humidity @ 25°C | 0-95% |
| Max. Altitude above Sea Level without De-rating (M) | ≤1000 m |
PHYSICAL
| Dimension (W x D x H) in mm | 370 x 400 x 320 | 370 x 510 x 550 | 370 x 530 x 620 | 370 x 530 x 620 |
|---|---|---|---|---|
| Net Weight (Kg) | 28.97 | 43.79 | 64.57 | 67.28 |
| Gross Weight (Kg) | 31.3 | 46.5 | 69.6 | 70.8 |
| Technical Parameters are subject to change without any prior notice | MPPT - SOLAR UPS |
|---|---|
| MPPT Solar UPS are high efficiency Solar Inverter which comes | with Interleaved MPPT technology to extract Solar energy with minimum losses. This solar inverter has RTC (Real Time Clock) feature, that renders optimum solar power and also manages your grid usage to provide maximum savings. |
2
*35% Enhanced solar generation
| Next-Gen | MPPT Technology |
|---|---|
| Years Warranty | Upto 35% more Solar Generation Increased Solar output w.r.t Solar PWM technology |
| MPPT - Solar UPS | Advanced Interleaved MPPT Technology More than 95% efficiency in Solar Inverters Minimized losses |
| Real-Time Clock (RTC) feature | In-Built RTC Logics for prioritizing, battery/grid to get more backup and savings |
| Smart Solar Selection | Three Different Saving Levels for maximum Solar Utilization. |
| Normal/SGB/SBG | Integrated Protections for More safety Battery Low, Over Temp, Short Circuit protections. |
| 150% Overload Capacity | UPS/Normal Mode |
| Suitable for computer load as well as areas with low voltage |  |
| Model Name: | LS OG1000M | LS OG2200M | LS OG2500M |
|---|---|---|---|
| 1000VA /12V | 2200VA /24V | 2500VA /24V | |
| 12V | 24V | 24V | |
| 180 ± 10V | |||
| 9-12V Hysterisis from > Low Cut Voltage | |||
| 270 ± 10V | |||
| 9-12V Hysterisis from > High Cut Voltage | |||
| 90 ± 10V | 100 ± 10V | ||
| 9-12V Hysterisis from > Low Cut Voltage | |||
| 290 ± 10V | |||
| 9-12V Hysterisis from > High Cut Voltage | |||
| 45-55 Hz | |||
| Backup Mode | |||
| 225± 7 V | |||
| 50 ± 1 Hz | |||
| PURE SINE WAVE | |||
| 10.8V ± 0.2 V | |||
| 10.6V ± 0.2 V | |||
| Battery | |||
| 1 | 2 | 2 | |
| 13.7 ± 0.2VDC (Default) | |||
| 14.4 ± 0.2VDC (Deafult) | |||
| 13.5 ± 1A | 15 ± 1A | ||
| 18 ± 1A | 20 ± 1A | ||
| 40A (settable 5A to 50A) | |||
| MPPT Interleaved Channel | |||
| 800W | 2500W | 3200W | |
| (30±1)A | (30±1)A | (40±1) A | |
| 60V | 110V | 110V | |
| 25V | 36V | 36V | |
| 50V | 88V | 88V | |
| ≥92% | ≥95% | ||
| Trip, PV Reverse | |||
| Solar KWH, Solar Current on Load, Solar Current on Battery, Mains On, Output Voltage, Time | |||
| 1. Saving Level 1 - Normal Mode | |||
| 2. Saving Level 2 - SGB Mode | |||
| 3. Saving Level 2 - SBG Mode | |||
| IP20 (indoor Use) | |||
| 0 to 55°C | |||
| 314X276X232 | 314X276X232 | 314X276X232 | |
| 380X375X320 | 380X375X320 | 380X375X320 | |
| NetWeight | 12.260Kg | 17.00Kg | 19.33Kg |
| GrossWeight | 13.530Kg | 18.370Kg | 20.70Kg |
MPPT POWER CONDITIONING UNIT
& LED Display
FEATURES
Enhanced Solar Power Utilization with Priority Mode
No PV overload tripping via limiting feature to
ensure generation does not fully stop
Greater PV power allowed per KVA along with a wide MPPT voltage range
Fast Battery Charging
5
Charging from Grid + Solar
Multiple Battery Selection available, Flat/Tubular/VRLA
Safety & Protection
Smart thermal management
In-built battery, inverter and panel protection
MCB protection at all Inputs and Outputs
UPS/Unregulated Mode
Wide range for poor grids where voltage frequently comes down
Best in Class Overload Capability
Upto 200% overload for peak surges Multiple overload attempts allowed
Livguard Solar Hybrid MPPT HKVA Inverters are high capacity, enhanced efficiency solar PCU that runs both on solar & utility (grid) power supply. It comes with Priority Mode (ECO/GRID/NONSOLAR) feature for maximizing savings and extended backup.

Advanced MPPT algorithm extracts maximum power from PV modules to both run your appliances and charge your batteries.
Pure Sine Wave
Noiseless & long life operations of electrical appliances.
MPPT POWER CONDITIONING UNIT
| Model No. | LS OG3048M | LS OG5048M | LS OG7500M | LS OG10000M | LS OG15000M |
|---|---|---|---|---|---|
| 3KVA/48V | 5KVA/48V | 7.5KVA/96V | 10KVA/120V | 15KVA/240V |
MAINS INPUT MODE
| Mains AC Low Cut (UPS Mode) | 180 ± 5V | 170 ± 5V |
|---|---|---|
| Mains AC Low Cut Recovery (UPS Mode) | 9-12V Hysterisis from > Low Cut Voltage | |
| Mains AC High Cut (UPS Mode) | 260 ± 5V | 270 ± 5V |
| Mains AC High Cut Recovery (UPS Mode) | 9-12V Hysterisis from < High Cut Voltage | |
| Mains AC Low Cut (Wide Range Mode) | 120 ± 5V | 170 ± 5V |
| Mains AC Low Cut Recovery (Wide range Mode) | 9-12V Hysterisis > Low Cut Voltage | |
| Mains AC High Cut (Wide Range Mode) | 280 ± 5V | 270 ± 5V |
| Mains AC High Cut Recovery (Wide Range Mode) | 9-12V Hysterisis < High Cut Voltage | |
| Input Frequency Range | 50 ± 5% Hz | |
| Output voltage in Mains mode | Same as Mains Input | |
| Output frequency in Mains mode | Same as Mains Input |
BATTERY
| Battery Type | TUBULAR | ||||
|---|---|---|---|---|---|
| VRLA | |||||
| FLAT PLATE | |||||
| DC Input Voltage (Nominal) | 48V | 48V | 96V | 120V | 240V |
| Battery Quantity (12V 100Ah to 220Ah) | 4 | 4 | 8 | 10 | 20 |
| Float Charging Voltage (Tubular/VRLA/Flat Plate) | 13.2/13.5/13.4 (per Battery ) ± .5V | ||||
| Boost Charging Voltage(Tubular/VRLA/Flat Plate) | 14.5/13.8/13.7 (per Battery ) ± .5V | ||||
| Boost Charging Voltage Range for Tubular and SMF Battery | Provided Above | ||||
| Bulk Absorption Battery Voltage | Same as Above | ||||
| Battery Deep Discharge Recovery | YES | ||||
| Charging Current By Grid | 20.0 ± 1.0A | 30.0 ± 1.0A | 25.0 ± 1.0A | 35.0 ± 1.0A | 30.0 ± 1.0A |
| Charging Current By PV | Provided Above |
BACKUP MODE
| Output Voltage | 230 ± 2% V | ||||
|---|---|---|---|---|---|
| Output Frequency | 50 ± 0.5 Hz | ||||
| Output Waveform | PURE SINE WAVE | ||||
| No Load Current (Switch OFF) | Sleep Mode is not Provided Currently | ||||
| Discharging Current @ Full Load | 10.5 A± 1 Amp. | 17.5 A ± 1 Amp. | 26 A± 1 Amp. | 35 A± 1 Amp. | 52 A± 1 Amp. |
| Low Battery Warning | 11.1V (per Battery ) ± 0.2V | ||||
| Low Battery Cut | 10.8V (per Battery ) ± 0.2V | ||||
| Change Over Time From Mains To Inverter (Unregulated Mode) | ≤ 25 msec | ≤ 25 msec | |||
| Change Over Time From Inverter To Mains (Unregulated Mode) | ≤ 25 msec | ≤ 25 msec | |||
| Change Over Time From Mains To Inverter (UPS Mode) | ≤ 20 msec | ≤ 25 msec | |||
| Change Over Time From Without Inverter To Mains (UPS Mode) | ≤ 20 msec | ≤ 25 msec | |||
| Cooling | FORCED COOLING BY FAN |
PROTECTIONS
| Overload in Backup Mode | YES |
|---|---|
| Short Circuit in Backup Mode | YES |
| Short Circuit in Mains Mode | Mains MCB Trip |
| Backfeed | YES |
| Over Temperature | YES |
| Reverse Battery | YES |
| Phase to Phase Protection in Mains Mode | YES |
SOLAR CHARGE CONTROLLER
MPPT POWER CONDITIONING UNIT
| Solar Charge Controller | |||||
|---|---|---|---|---|---|
| Maximum Battery Current | 60A | 100A | 75A | 80A | 60A |
| 94% | 95% | ||||
| Reverse PV Protection | YES | ||||
| Reverse Current Flow to PV | NO | ||||
| Switching Element(MPPT Charger ) | IGBT | ||||
| DOD (Depth of Discharge) | As per battery voltage setting (1.8V/cell) |
DISPLAY AND ALARMS
| LCD Display Parameters | 1. Battery Voltage & Current |
|---|---|
| 2. PV Voltage & Current | |
| 3. PV Power, Total Generation & Today’s Genration | |
| 4. Mains Voltage & Frequency | |
| 5. Load Voltage, Current & Frequency (Inverter Mode Only) | |
| 6. Load Power | |
| 7. Battrey Charging/Discharging Status | |
| 8. Time & Date | |
| 9. User Settings & Factory Settings | |
| LCD Fault/Protection Status Display | i) Overload |
| ii) Short Circuit | |
| iii) Battery & PV Reverse Polarity | |
| iv) Battrey Over/Under Voltage | |
| v) Battery Current Limit | |
| vi) Mains Over/Under Voltage | |
| vii) System Over Temprature | |
| viii) Grid/Load/PV Surge Protection(MOV) | |
| Buzzer | YES |
SAFETY
| HV Test Input to Earth | YES |
|---|---|
| HV Test Output to Earth | YES |
| IR Test Input to Earth | YES |
| IR Test Output to Earth | YES |
ENVIRONMENT
| Operating Temperature | 0°C to 50°C |
|---|---|
| Storage Temperature | 10°C to 70°C |
| Operating Relative Humidity | 5-95% (Non-condensed) |
DIMENSIONS
| Dimensions in mm (LXWXH) | 325X295X415 | 448.5X275X611 | 650X400X753.5 | 650X400X753.5 | 650X450X753.5 | |
|---|---|---|---|---|---|---|
| Box Dimensions in mm (LXWXH) | 680X345X510 | 680X345X510 | 835X495X800 | 835X495X800 | 835X565X800 | |
| Weight in Kg | Net Weight | 31.0Kg | 52.95Kg | 97.5Kg | 104.35Kg | 138.40Kg |
| Gross Weight | 33.5Kg | 55.55Kg | 109.85Kg | 116.70Kg | 153.45Kg | |
| NOTE |
| Solar Charge Controller Type | MPPT | ||||
|---|---|---|---|---|---|
| Max Panel Wattage That Can Be Connected | 3300W | 5500W | 8250W | 11000W | 16500W |
| Max No. of (@335 Wp) Panels Connected (S:Series, P: Parallel) | S: 3, P: 3 | S: 4, P: 4 | S: 7, P: 4 | S: 7, P: 5 | S:12,P:4 |
| Min No. of (@335 Wp) Panels Connected (S:Series, P: Parallel) | S: 3, P: 1 | S: 3, P: 1 | S: 5, P: 1 | S: 5, P: 1 | S:10,P:1 |
| No. of Input Channel | 1 | 1 | 1 | 1 | 1 |
| Max. input Current per Channel (Maximum Isc) | ( 30 ± 1)A | (50 ± 1)A | (50 ± 1)A | (57 ± 1)A | (57 ± 1)A |
| Maximum PV Voltage Voc | ( 190 ± 5)V | ( 320 ± 5)V | (700 ±5)V | ||
| Minimum PV Voltage Vmp | 70V | 175V | 350V | ||
| Maximum PV Voltage Vmp | ( 160 ± 5)V | ( 266 ± 5)V | (560 ± 5)V |
GIH INVERTER - 1 PHASE
Grid Interactive Hybrid Inverters are also known as GIH inverters.
With a wide operating temperature range and suitable for operation in harsh environments, these machines are a perfect fit for low maintenance, off-grid/ hybrid installations of industrial
GRID INTERACTIVE HYBRID INVERTER - 1 PHASE
Model Name
| 3KVA | 5KVA |
|---|
MAINS INPUT MODE
| 170 ± 5V | 170 ± 5V |
|---|---|
| 10V Hysteresis from > Low Cut Voltage | |
| 265 ± 5V | 265 ± 5V |
| 10V Hysteresis from < High Cut Voltage | |
| 47-53Hz |
MAINS EXPORT MODE
| Same as Mains Voltage | |
|---|---|
| 2400W | 4000W |
Scheduled Grid Usage
Manage start/stop battery charging from grid/solar effectively
Limit Import Power from Grid
and residential nature both.
Smart Charging Control
Priority/Non-Priority Solar operation Use Solar Power for both type of Loads. Connect Upto 20Kva Load on Non-Priority.
Years Warranty
3-Stage Battery Charging Float, Bulk & Equalization Ensure long life of the battery
5
BATTERY
| 48V | |
|---|---|
| 4 | |
| 13.2/13.5/13.4 (per Battery ) ± .5V | |
| 14.5/13.8/13.7 (per Battery ) ± .5V | |
| YES | |
| Half of Solar Charging Current | |
| 60.0 ± 1.0A | 100.0 ± 1.0A |
BACKUP MODE
| 50 ± 0.5 Hz | |
|---|---|
| PURE SINE WAVE | |
| <100W | <150W |
| 10.5 A± 1 Amp. | 17.5 A ± 1 Amp. |
| 11.1V (per Battery ) ± 0.2V | |
| 10.8V (per Battery ) ± 0.2V |
PROTECTIONS
SOLAR CHARGE CONTROLLER
| MPPT | |
|---|---|
| 3300W | 5500W |
| 1 | 1 |
| ( 30 ± 1)A | (50 ± 1)A |
| ( 190 ± 5)V | |
| 70V | |
| ( 160 ± 5)V | |
| 60A | 100A |
| YES | |
| NO | |
| IGBT |
In-Built Zero Export
No separate device required.
Use Solar On-Grid without Net Metering.
10 ms
MPPT
Seamless Switching <10ms Switch between inverter/mains without any interruptions.
MPPT-Based Solar Charge Controller
Highly Efficient MPPT technology for maximum solar utilization.
MODES OF OPERATIONS
DISPLAY AND ALARMS
LCD FAULT/PROTECTION STATUS DISPLAY
ENVIRONMENT
| 0°C to 50°C |
|---|
DIMENSIONS

55kgs
625X300X475MM
NOTE: Specifications are subject to change without prior notice
GRID INTERACTIVE HYBRID INVERTER
- 3PHASE
FEATURES
Battery Less Operation
2
Redundant Power Supply (Grid & DG): Twin Power supply to improve the power availability for the operation of PCU
Graphical Display with Real-Time Operational Graph:
Realtime SLD logic for easy understanding for the system operations.
In-built safety for High Temp, Smoke and Reverse Polarity
PCU will shut down in case of fire/smoke and protects the connected loads and the system.
NO Break Changeover:
No time delay during changeover from Solar to Battery or Grid and vice-versa.
Unbalanced Load Operation Prevents system trip during in the unbalancing load condition
100% Single phase, 50-50 unbalance,
33-33-33, equal balance
Grid Interactive Hybrid Solar Inverter - Three phase in-Three Phase out inverter gives maximum performance and reliability to run your heavy duty appliances. This inverter enables you to have the flexibility to be used as a On-Grid, Off-Grid or Hybrid Inverter as per your convenience

Minimized Internal Losses High perfotmance and efficient controler
Eliminate input current harmonics
GRID INTERACTIVE HYBRID INVERTER - 3PHASE

| IP 20 |
|---|
| Bottom |
| Output Group | |
|---|---|
| Output Group | 1. Solar Voltage , 2. Solar Current, 3. Power( kW), 4. Solar Energy (kWh) |
| Battery Group | 1. Voltage, 2.Current 3. Charging Status |
| MPPT | |||||
|---|---|---|---|---|---|
| 11 | 13.8 | 16.5 | 22 | 27.5 | 33 |
| 300V | 300V | 300/500 V | 500V | 500V | 500/600V |
| 165-250V | 165-250V | 165-250Vfor 120VDC / 300-450V for240VDC | 300-450V for 240VDC / 450-600V for 360VDC | ||
| 60 A | 75 A | 90 A for 120VDCand 50A for 240VDC | 66 A for240VDC and 44 A for 360VDC | 83 A for240VDC and 55 A for 360VDC | 100A for 240VDCand 66 A for 360VDC |
| S: 5 P: 9 | S:10 P: 6 | S: 9 P: 8 | S:10 P: 9 | ||
| S: 5 P: 6 | S: 6 P: 6 | S: 9 P: 5 | S: 12 P: 5 | S: 12 P: 6 | S: 13 P: 7 |
| 1 | |||||
| Yes |
| -perature |
|---|
| Solar Group |
| Battery Group |
| YES |
|---|
| Near to Unity |
| Continuous |
| >=10 kA |
| YES SAME AS INVERTER CAPACITY |
| -10 Deg C to 60 Deg C |
|---|
| < 1000 meter above sea level |
| upto 0.5g |
| Model Name | |||||
|---|---|---|---|---|---|
| 10 | 12.5 | 15 | 20 | 25 | 30 |
| Enable / Disable option Available |
|---|
| Enable / Disable option Available |
| 120 | 120 | 120/240 | 240 | 240/360 |
|---|---|---|---|---|
| SETTABLE THROUGH Key PAD | ||||
| YES | ||||
| YES |
| RS 232 or RS 485 | |
|---|---|
| Protocol | MODBUS RTU |
| YES | |
| (Earth bus bar running along the panel) |
| 34 | 43 | 54 | 69 | 86 | 104 |
|---|---|---|---|---|---|
| Pure Sine wave | |||||
| No Break Change Over Time | |||||
| In built Isolation Transformer at Inverter Output | |||||
| YES | |||||
| YES |
| 10 | 12.5 | 15 | 20 | 25 | 30 |
|---|---|---|---|---|---|
| 450 | 450 | 450 | 450 | 450 | 600 |
| 800 | 800 | 800 | 800 | 950 | 1000 |
| 800 | 800 | 800 | 800 | 800 | 1300 |
| 150 | 150 | 150 | 300 | 350 | 600 |
SERVICE NETWORK
NOW SERVING COUNTLESS STATES ACROSS THE COUNTRY
650+
Trained Service Engineers
40+
On-Site* Service Facility
Solar Panel, UPS, PCU, SCC & SMU: Customer End
- Battery: CSC location
Service centre locations Pan India

18001025551